Generate digital District Of Columbia Architect stamps instantly

  • STATE BOARD APPROVED
  • HIGH-QUALITY FILES IN VARIOUS FORMATS
  • INSTANT ACCESS
  • FREE-OF-CHARGE REVISIONS
Loading seal preview
Text Size
Text Size

Your board-compliant seal will be ready for download after purchase

District of Columbia Architect Stamp Requirements

Board approved

Your District of Columbia Architect seal from pedigitalstamps.com meets every requirement on this page — the required wording and the layout set out in 17 DCMR § 3413 (Seal of an Architect). Fill in your details and download it in seconds.

The District of Columbia rules in full, with citations

The "typically 1¾ inches" figure repeated for the District has no source in DC law; § 1516.4 states no dimension. DCRA, whose URLs still circulate for this board, ceased to exist on October 1, 2022 when it was split into the Department of Licensing and Consumer Protection and the Department of Buildings. Chapter 17-23 is not the engineering chapter.

Architect seal

Board:
District of Columbia Board of Architecture, Interior Design, and Landscape Architecture
Diameter:
No numeric diameter is stated. The seal must comply in all respects, including size and format, with the specimen printed in the rule.
Legend:
“LICENSED ARCHITECT-DISTRICT OF COLUMBIA”
  • The seal contains the name of the licensed architect, the license number, and the words LICENSED ARCHITECT-DISTRICT OF COLUMBIA. The District does not use "Registered Architect". (17 DCMR § 3413.1)
  • The architect affixes their name, by manual or electronic signature, across the printed image of the seal. (17 DCMR § 3413.7)
  • An electronic signature must be unique to the architect, verifiable, under sole control, and linked to the document so that it is invalidated if any data in the document changes. (17 DCMR § 3413.7)

Full District of Columbia Architect seal requirements, with every citation →

File formats

All formats included

 format preview

HIGH-QUALITY RASTER FORMAT

 format preview

VECTOR FORMAT, INFINITELY SCALABLE

 format preview

UNIVERSAL DOCUMENT FORMAT

 format preview

AUTOCAD COMPATIBLE FORMAT

 format preview

PROFESSIONAL PRINT FORMAT

How it works

Create your District Of Columbia digital Architect stamp

1

Select your state & profession

2

Add your name & license number

3

Adjust the text size using the controls

4

Select your discipline

5

Add your signature & customize (optional)

6

Download instantly to your computer

Electronic PE Stamp

Software compatibility

Compatible with PDF and CAD software

Bluebeam
Adobe Acrobat
Bluebeam Stamp Example
Click to expand
AutoCAD
Autodesk Revit
AutoCAD Stamp Example
Click to expand

Who we are

About

Our digital District Of Columbia Architect stamp generator creates instant state-approved electronic architect stamps. Our platform provides full customization of your digital seal, including an option to add your signature. Professional Engineer (PE) stamps, Architect stamps, and Land Surveyor stamps are available for immediate download after customization. There is no waiting. Every electronic professional seal we generate is 100% compliant with state board requirements, ensuring your digital stamp meets all necessary standards.

State boards

State board-approved, including

Florida PE Stamp logo
Texas PE Stamp logo
California PE Stamp logo
Georgia PE Stamp logo
New York PE Stamp logo
Pennsylvania PE Stamp logo

FAQ

District Of Columbia Architect Seal FAQs

Frequently asked questions about District Of Columbia digital architect stamps and seals.

How do I obtain a digital District of Columbia architect seal or stamp?

Once you are licensed in District of Columbia, you can generate your seal here and download it immediately. Fill in the form and position your signature if you want one. The layout follows 17 DCMR § 3413 (Seal of an Architect), which is the provision the District of Columbia Board of Architecture, Interior Design, and Landscape Architecture will measure the seal against.

What are the requirements for the District of Columbia architect stamp or seal?

District of Columbia’s architect stamp rule is 17 DCMR § 3413 (Seal of an Architect), administered by the District of Columbia Board of Architecture, Interior Design, and Landscape Architecture, a different body from the engineering board. The seal must carry “LICENSED ARCHITECT-DISTRICT OF COLUMBIA”, and no numeric diameter is stated. The seal must comply in all respects, including size and format, with the specimen printed in the rule.

A further 3 requirements, each tied to the subsection that imposes it, are itemised in the District of Columbia requirements section on this page.

What size does a District of Columbia architect stamp have to be?

17 DCMR § 3413 (Seal of an Architect) governs the District of Columbia architect’s seal but does not prescribe a diameter. Sizes quoted for District of Columbia elsewhere generally come from stamp suppliers’ catalogues rather than from the rule. What the rule does require is that your name and license number stay clearly legible.

Does the DC engineering board set the architect's seal rules?

No. Architects answer to the Board of Architecture, Interior Design, and Landscape Architecture, and the seal provision is 17 DCMR § 3413 in Chapter 17-34. The Board of Professional Engineers and Land Surveyors and its seal rule, 17 DCMR § 1516 in Chapter 17-15, govern engineers and surveyors and say nothing about architects — so an architect who follows the § 1516 list ends up with the wrong words on the seal. (17 DCMR § 3413; 17 DCMR § 1516)

Does a District of Columbia architect's seal say "Registered Architect"?

No. 17 DCMR § 3413.1 fixes the wording as LICENSED ARCHITECT-DISTRICT OF COLUMBIA — one hyphenated phrase, not two elements — together with the name of the licensed architect and the license number. The section states no diameter; the seal "shall comply in all respects, including size and format, with the specimen shown below", so the printed specimen rather than a number is the standard to match. (17 DCMR § 3413.1)

Where does a District of Columbia architect sign in relation to the seal?

Across it. 17 DCMR § 3413.7 requires the licensed architect, when affixing the seal to any technical submission or other instrument of service, to affix their name by manual or electronic signature across the printed image of the seal. The engineering rule is the looser one — 17 DCMR § 1516.9 lets an engineer or surveyor sign adjacent to or across the seal — but the architect's rule offers no adjacent option. (17 DCMR § 3413.7)

Does a DC architect seal every drawing or only the cover sheet?

Every drawing. 17 DCMR § 3413.2 imprints the seal on each design and each drawing, on the cover and index pages identifying each set of specifications, and on the cover page and index of all other technical submissions. § 3413.8 adds a requirement that is easy to overlook: all technical submissions or other instruments of service shall be identified as architecture documents. (17 DCMR § 3413.2, § 3413.8)

May a DC architect keep sealing after a license suspension?

No. 17 DCMR § 3413.6 provides that the seal shall not be used for any purpose after a revocation or suspension takes effect — the same section that gives the architect thirty days to surrender the seal to the secretary of the Board. A seal image sitting in a template or a CAD block is no exception; the bar is on use, whatever form the seal takes. Where a suspension runs for a fixed period, the seal is returned when that period expires. (17 DCMR § 3413.6)